TECHNICAL DETAILS
Main Unit | Electrostimulation |
---|---|
No of outputs: | 4 |
Wave shape: | Compensated rectangular |
Width of impulses: | 50 – 200µSec |
No of programs: | 7 + 1 set-up program |
Current intensity: | 70 mA (peak on impulse, load 1KOhm) |
Power supply: | 4 alkaline batteries 1,5V AA type or 1 rechargeable battery pack Ni-Mh 4,8V-1.000 mA/h (normally supplied) or its supply power |
Dimensions: | 118 x 125 x h1 49 x h2 21 mms |
Contraction times: | 1-10 sec. |
Recovery time: | 1-8 sec. |
Frequency range: | 1-100 Hz |
Weight: | 300 g (with Ni-Mh battery pack) |
Marking: | ![]() |
Ultrasound Unit | |
---|---|
Ultrasound frequency: | 1Mhz ±5% |
Wave shape: | Sinusoidal |
Output power: | 2W |
No of programs: | 4 + manual function |
emitting surface: | 12cm² |
Power supply: | AC adapter 12VDC 1,2A |
Dimensions: | 120 x 49 x 45 mms |
Treatment times: | 15 min. with automatic switch off |
emission type: | Continuous pulsed |
Power regulation: | 20-40-60-80-100% |
Weight: | 203 g |
Marking: | ![]() |
Twin-Up-t7 Sonic is safe
Twin-Up T7 Sonic bears CE mark
The design and production of Twin-Up T7 Sonic were carried out in compliance with the requirements imposed by the company Quality System pursuant to UNI EN ISO 9001: 2008 and UNI EN ISO 13485: 2004.
Contraindications Twin-Up-t7 Sonic
• During the menstrual period, skin conduction changes;
stimulation could prove less comfortable.
• Stimulation causes reddening of the skin where the electrodes are placed, especially in the case of persons with sensitive skin.
Such reddening is perfectly normal and usually disappears quickly.
• In case of allergy to the electrode gel, suspend treatment and see a doctor.
• Do not apply the electrodes to areas with hyperpigmentation (moles) or varicose veins.
• Do not apply the electrodes directly to the breasts, but to the muscles which
support them.
• Do not use in intimate areas, under the armpits, in the groin or behind the knees.
• Do not use on the abdomen of expectant mothers.
• Do not use Twin-Up-t7 Sonic on children, people with pace-makers or those in poor psychophysical conditions or with physiological or organic disorders.
poor psychophysical conditions or with physiological or organic disorders.
• The appliance is not suited for wearers of metal prostheses or aortoabdominal bypasses.
• Do not apply in transthoracic mode to prevent interference with heart
frequency.
• Do not apply ultrasound to the intercostal grid and generally to the lower abdomen,
heart, head.
• IN CASE OF DOUBT, SEE A DOCTOR
If adhesive gel electrodes of other brands are used, keep strictly
to the following instructions:
electrode dimensions: 3.5×4.5 cms. or 9×4 cms.
Minimum electrode surface: 15 sq cms